DCMTK  Version 3.6.1 20120515
OFFIS DICOM Toolkit
Public Member Functions | Private Attributes
DRTSetupDeviceSequence::Item Class Reference

Item class. More...

+ Inheritance diagram for DRTSetupDeviceSequence::Item:

List of all members.

Public Member Functions

 Item (const OFBool emptyDefaultItem=OFFalse)
 (default) constructor
 Item (const Item &copy)
 copy constructor
virtual ~Item ()
 destructor
Itemoperator= (const Item &copy)
 assigment operator
void clear ()
 clear all internal member variables
OFBool isEmpty ()
 check if item is empty
OFBool isValid () const
 check if item is valid, i.e. not the empty default item
OFCondition read (DcmItem &item)
 read elements from sequence item
OFCondition write (DcmItem &item)
 write elements to sequence item
OFCondition getSetupDeviceDescription (OFString &value, const signed long pos=0) const
 get SetupDeviceDescription (300a,01ba)
OFCondition getSetupDeviceLabel (OFString &value, const signed long pos=0) const
 get SetupDeviceLabel (300a,01b8)
OFCondition getSetupDeviceParameter (OFString &value, const signed long pos=0) const
 get SetupDeviceParameter (300a,01bc)
OFCondition getSetupDeviceParameter (Float64 &value, const unsigned long pos=0) const
 get SetupDeviceParameter (300a,01bc)
OFCondition getSetupDeviceType (OFString &value, const signed long pos=0) const
 get SetupDeviceType (300a,01b6)
OFCondition getSetupReferenceDescription (OFString &value, const signed long pos=0) const
 get SetupReferenceDescription (300a,01d0)
OFCondition setSetupDeviceDescription (const OFString &value, const OFBool check=OFTrue)
 set SetupDeviceDescription (300a,01ba)
OFCondition setSetupDeviceLabel (const OFString &value, const OFBool check=OFTrue)
 set SetupDeviceLabel (300a,01b8)
OFCondition setSetupDeviceParameter (const OFString &value, const OFBool check=OFTrue)
 set SetupDeviceParameter (300a,01bc)
OFCondition setSetupDeviceType (const OFString &value, const OFBool check=OFTrue)
 set SetupDeviceType (300a,01b6)
OFCondition setSetupReferenceDescription (const OFString &value, const OFBool check=OFTrue)
 set SetupReferenceDescription (300a,01d0)

Private Attributes

OFBool EmptyDefaultItem
 internal flag used to mark the empty default item
DcmShortText SetupDeviceDescription
 SetupDeviceDescription (300a,01ba) vr=ST, vm=1, type=3.
DcmShortString SetupDeviceLabel
 SetupDeviceLabel (300a,01b8) vr=SH, vm=1, type=2C.
DcmDecimalString SetupDeviceParameter
 SetupDeviceParameter (300a,01bc) vr=DS, vm=1, type=2C.
DcmCodeString SetupDeviceType
 SetupDeviceType (300a,01b6) vr=CS, vm=1, type=1C.
DcmShortText SetupReferenceDescription
 SetupReferenceDescription (300a,01d0) vr=ST, vm=1, type=3.

Detailed Description

Item class.


Constructor & Destructor Documentation

DRTSetupDeviceSequence::Item::Item ( const OFBool  emptyDefaultItem = OFFalse)

(default) constructor

Parameters:
emptyDefaultItemflag used to mark the empty default item

copy constructor

Parameters:
copyitem object to be copied

Member Function Documentation

OFCondition DRTSetupDeviceSequence::Item::getSetupDeviceDescription ( OFString value,
const signed long  pos = 0 
) const

get SetupDeviceDescription (300a,01ba)

Parameters:
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1), -1 for all components
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::getSetupDeviceLabel ( OFString value,
const signed long  pos = 0 
) const

get SetupDeviceLabel (300a,01b8)

Parameters:
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1), -1 for all components
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::getSetupDeviceParameter ( OFString value,
const signed long  pos = 0 
) const

get SetupDeviceParameter (300a,01bc)

Parameters:
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1), -1 for all components
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::getSetupDeviceParameter ( Float64 &  value,
const unsigned long  pos = 0 
) const

get SetupDeviceParameter (300a,01bc)

Parameters:
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1)
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::getSetupDeviceType ( OFString value,
const signed long  pos = 0 
) const

get SetupDeviceType (300a,01b6)

Parameters:
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1), -1 for all components
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::getSetupReferenceDescription ( OFString value,
const signed long  pos = 0 
) const

get SetupReferenceDescription (300a,01d0)

Parameters:
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1), -1 for all components
Returns:
status, EC_Normal if successful, an error code otherwise

check if item is empty

Returns:
OFTrue if item is empty, OFFalse otherwise

check if item is valid, i.e. not the empty default item

Returns:
OFTrue if item is valid, OFFalse otherwise
Item& DRTSetupDeviceSequence::Item::operator= ( const Item copy)

assigment operator

Parameters:
copyitem object to be copied

read elements from sequence item

Parameters:
itemreference to DICOM sequence item from which the elements should be read
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::setSetupDeviceDescription ( const OFString value,
const OFBool  check = OFTrue 
)

set SetupDeviceDescription (300a,01ba)

Parameters:
valuevalue to be set (single value only) or "" for no value
checkcheck 'value' for conformance with VR (ST) and VM (1) if enabled
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::setSetupDeviceLabel ( const OFString value,
const OFBool  check = OFTrue 
)

set SetupDeviceLabel (300a,01b8)

Parameters:
valuevalue to be set (single value only) or "" for no value
checkcheck 'value' for conformance with VR (SH) and VM (1) if enabled
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::setSetupDeviceParameter ( const OFString value,
const OFBool  check = OFTrue 
)

set SetupDeviceParameter (300a,01bc)

Parameters:
valuevalue to be set (single value only) or "" for no value
checkcheck 'value' for conformance with VR (DS) and VM (1) if enabled
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::setSetupDeviceType ( const OFString value,
const OFBool  check = OFTrue 
)

set SetupDeviceType (300a,01b6)

Parameters:
valuevalue to be set (single value only) or "" for no value
checkcheck 'value' for conformance with VR (CS) and VM (1) if enabled
Returns:
status, EC_Normal if successful, an error code otherwise
OFCondition DRTSetupDeviceSequence::Item::setSetupReferenceDescription ( const OFString value,
const OFBool  check = OFTrue 
)

set SetupReferenceDescription (300a,01d0)

Parameters:
valuevalue to be set (single value only) or "" for no value
checkcheck 'value' for conformance with VR (ST) and VM (1) if enabled
Returns:
status, EC_Normal if successful, an error code otherwise

write elements to sequence item

Parameters:
itemreference to DICOM sequence item to which the elements should be written
Returns:
status, EC_Normal if successful, an error code otherwise

The documentation for this class was generated from the following file:


Generated on Tue May 15 2012 for DCMTK Version 3.6.1 20120515 by Doxygen 1.7.5.1-20111027