DCMTK
Version 3.6.1 20120515
OFFIS DICOM Toolkit
|
Public Member Functions | |
Item (const OFBool emptyDefaultItem=OFFalse) | |
(default) constructor | |
Item (const Item ©) | |
copy constructor | |
virtual | ~Item () |
destructor | |
Item & | operator= (const Item ©) |
assigment operator | |
void | clear () |
clear all internal member variables | |
OFBool | isEmpty () |
check if item is empty | |
OFBool | isValid () const |
check if item is valid, i.e. not the empty default item | |
OFCondition | read (DcmItem &item) |
read elements from sequence item | |
OFCondition | write (DcmItem &item) |
write elements to sequence item | |
OFCondition | getIsocenterToRangeModulatorDistance (Float32 &value, const unsigned long pos=0) const |
get IsocenterToRangeModulatorDistance (300a,038a) | |
OFCondition | getRangeModulatorGatingStartValue (Float32 &value, const unsigned long pos=0) const |
get RangeModulatorGatingStartValue (300a,0382) | |
OFCondition | getRangeModulatorGatingStartWaterEquivalentThickness (Float32 &value, const unsigned long pos=0) const |
get RangeModulatorGatingStartWaterEquivalentThickness (300a,0386) | |
OFCondition | getRangeModulatorGatingStopValue (Float32 &value, const unsigned long pos=0) const |
get RangeModulatorGatingStopValue (300a,0384) | |
OFCondition | getRangeModulatorGatingStopWaterEquivalentThickness (Float32 &value, const unsigned long pos=0) const |
get RangeModulatorGatingStopWaterEquivalentThickness (300a,0388) | |
OFCondition | getReferencedRangeModulatorNumber (OFString &value, const signed long pos=0) const |
get ReferencedRangeModulatorNumber (300c,0104) | |
OFCondition | getReferencedRangeModulatorNumber (Sint32 &value, const unsigned long pos=0) const |
get ReferencedRangeModulatorNumber (300c,0104) | |
OFCondition | setIsocenterToRangeModulatorDistance (const Float32 value, const unsigned long pos=0) |
set IsocenterToRangeModulatorDistance (300a,038a) | |
OFCondition | setRangeModulatorGatingStartValue (const Float32 value, const unsigned long pos=0) |
set RangeModulatorGatingStartValue (300a,0382) | |
OFCondition | setRangeModulatorGatingStartWaterEquivalentThickness (const Float32 value, const unsigned long pos=0) |
set RangeModulatorGatingStartWaterEquivalentThickness (300a,0386) | |
OFCondition | setRangeModulatorGatingStopValue (const Float32 value, const unsigned long pos=0) |
set RangeModulatorGatingStopValue (300a,0384) | |
OFCondition | setRangeModulatorGatingStopWaterEquivalentThickness (const Float32 value, const unsigned long pos=0) |
set RangeModulatorGatingStopWaterEquivalentThickness (300a,0388) | |
OFCondition | setReferencedRangeModulatorNumber (const OFString &value, const OFBool check=OFTrue) |
set ReferencedRangeModulatorNumber (300c,0104) | |
Private Attributes | |
OFBool | EmptyDefaultItem |
internal flag used to mark the empty default item | |
DcmFloatingPointSingle | IsocenterToRangeModulatorDistance |
IsocenterToRangeModulatorDistance (300a,038a) vr=FL, vm=1, type=3. | |
DcmFloatingPointSingle | RangeModulatorGatingStartValue |
RangeModulatorGatingStartValue (300a,0382) vr=FL, vm=1, type=1C. | |
DcmFloatingPointSingle | RangeModulatorGatingStartWaterEquivalentThickness |
RangeModulatorGatingStartWaterEquivalentThickness (300a,0386) vr=FL, vm=1, type=3. | |
DcmFloatingPointSingle | RangeModulatorGatingStopValue |
RangeModulatorGatingStopValue (300a,0384) vr=FL, vm=1, type=1C. | |
DcmFloatingPointSingle | RangeModulatorGatingStopWaterEquivalentThickness |
RangeModulatorGatingStopWaterEquivalentThickness (300a,0388) vr=FL, vm=1, type=3. | |
DcmIntegerString | ReferencedRangeModulatorNumber |
ReferencedRangeModulatorNumber (300c,0104) vr=IS, vm=1, type=1. |
Item class.
DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::Item | ( | const OFBool | emptyDefaultItem = OFFalse | ) |
(default) constructor
emptyDefaultItem | flag used to mark the empty default item |
DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::Item | ( | const Item & | copy | ) |
copy constructor
copy | item object to be copied |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::getIsocenterToRangeModulatorDistance | ( | Float32 & | value, |
const unsigned long | pos = 0 |
||
) | const |
get IsocenterToRangeModulatorDistance (300a,038a)
value | reference to variable in which the value should be stored |
pos | index of the value to get (0..vm-1) |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::getRangeModulatorGatingStartValue | ( | Float32 & | value, |
const unsigned long | pos = 0 |
||
) | const |
get RangeModulatorGatingStartValue (300a,0382)
value | reference to variable in which the value should be stored |
pos | index of the value to get (0..vm-1) |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::getRangeModulatorGatingStartWaterEquivalentThickness | ( | Float32 & | value, |
const unsigned long | pos = 0 |
||
) | const |
get RangeModulatorGatingStartWaterEquivalentThickness (300a,0386)
value | reference to variable in which the value should be stored |
pos | index of the value to get (0..vm-1) |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::getRangeModulatorGatingStopValue | ( | Float32 & | value, |
const unsigned long | pos = 0 |
||
) | const |
get RangeModulatorGatingStopValue (300a,0384)
value | reference to variable in which the value should be stored |
pos | index of the value to get (0..vm-1) |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::getRangeModulatorGatingStopWaterEquivalentThickness | ( | Float32 & | value, |
const unsigned long | pos = 0 |
||
) | const |
get RangeModulatorGatingStopWaterEquivalentThickness (300a,0388)
value | reference to variable in which the value should be stored |
pos | index of the value to get (0..vm-1) |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::getReferencedRangeModulatorNumber | ( | OFString & | value, |
const signed long | pos = 0 |
||
) | const |
get ReferencedRangeModulatorNumber (300c,0104)
value | reference to variable in which the value should be stored |
pos | index of the value to get (0..vm-1), -1 for all components |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::getReferencedRangeModulatorNumber | ( | Sint32 & | value, |
const unsigned long | pos = 0 |
||
) | const |
get ReferencedRangeModulatorNumber (300c,0104)
value | reference to variable in which the value should be stored |
pos | index of the value to get (0..vm-1) |
check if item is empty
OFBool DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::isValid | ( | ) | const |
check if item is valid, i.e. not the empty default item
assigment operator
copy | item object to be copied |
read elements from sequence item
item | reference to DICOM sequence item from which the elements should be read |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::setIsocenterToRangeModulatorDistance | ( | const Float32 | value, |
const unsigned long | pos = 0 |
||
) |
set IsocenterToRangeModulatorDistance (300a,038a)
value | value to be set (should be valid for this VR) |
pos | index of the value to be set (0..vm-1), vm=1 |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::setRangeModulatorGatingStartValue | ( | const Float32 | value, |
const unsigned long | pos = 0 |
||
) |
set RangeModulatorGatingStartValue (300a,0382)
value | value to be set (should be valid for this VR) |
pos | index of the value to be set (0..vm-1), vm=1 |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::setRangeModulatorGatingStartWaterEquivalentThickness | ( | const Float32 | value, |
const unsigned long | pos = 0 |
||
) |
set RangeModulatorGatingStartWaterEquivalentThickness (300a,0386)
value | value to be set (should be valid for this VR) |
pos | index of the value to be set (0..vm-1), vm=1 |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::setRangeModulatorGatingStopValue | ( | const Float32 | value, |
const unsigned long | pos = 0 |
||
) |
set RangeModulatorGatingStopValue (300a,0384)
value | value to be set (should be valid for this VR) |
pos | index of the value to be set (0..vm-1), vm=1 |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::setRangeModulatorGatingStopWaterEquivalentThickness | ( | const Float32 | value, |
const unsigned long | pos = 0 |
||
) |
set RangeModulatorGatingStopWaterEquivalentThickness (300a,0388)
value | value to be set (should be valid for this VR) |
pos | index of the value to be set (0..vm-1), vm=1 |
OFCondition DRTRangeModulatorSettingsSequenceInRTIonBeamsModule::Item::setReferencedRangeModulatorNumber | ( | const OFString & | value, |
const OFBool | check = OFTrue |
||
) |
set ReferencedRangeModulatorNumber (300c,0104)
value | value to be set (single value only) or "" for no value |
check | check 'value' for conformance with VR (IS) and VM (1) if enabled |
write elements to sequence item
item | reference to DICOM sequence item to which the elements should be written |