Bug #443
closed
- Status changed from New to Resolved
Fixed with commit d6b29fe15455da02927c. Solution was just to make --inetd and --exec-on-eostudy conflicting. The problem here is that the end of study detection works across different associations. Thus if you use storescu twice to transfer two images that are in the same study with two separate associations, they will only be counted as a single end of study. For this reason, the code doesn't trigger an end of study when an association is released. This problem also affects --fork on unix (tested with "storescp --exec-on-eostudy 'date;echo eostudy #p' --exec-on-reception 'date;echo reception #p' 1234 --output-directory /tmp/ --sort-conc-studies dcm-foo --fork --eostudy-timeout 1", no study is ever ended).
It might make sense to fix this differently in the future:
When we are exiting and a study end is still pending (lastStudySubdirectoryPathAndName is not empty), just execute that study end now. This means that with --fork and --inetd studies across different associations can't be detected, but at least it doesn't miss any studies and --exec-on-eostudy can be used.
(Patches welcome :P)
- Status changed from Resolved to Closed
Also available in: Atom