DCMTK Version 3.6.8
OFFIS DICOM Toolkit
Public Member Functions | Private Attributes | List of all members
DRTDoseCalibrationConditionsSequence::Item Class Reference

Item class. More...

+ Inheritance diagram for DRTDoseCalibrationConditionsSequence::Item:

Public Member Functions

 Item (const OFBool emptyDefaultItem=OFFalse)
 (default) constructor More...
 
 Item (const Item &copy)
 copy constructor More...
 
virtual ~Item ()
 destructor
 
Itemoperator= (const Item &copy)
 assignment operator More...
 
void clear ()
 clear all internal member variables
 
OFBool isEmpty ()
 check if item is empty More...
 
OFBool isValid () const
 check if item is valid, i.e. not the empty default item More...
 
OFCondition read (DcmItem &item)
 read elements from sequence item More...
 
OFCondition write (DcmItem &item)
 write elements to sequence item More...
 
OFCondition getAbsorbedDoseToMetersetRatio (Float64 &value, const unsigned long pos=0) const
 get AbsorbedDoseToMetersetRatio (300c,0121) More...
 
OFCondition getCalibrationDateTime (OFString &value, const signed long pos=0) const
 get CalibrationDateTime (0018,1203) More...
 
OFCondition getCalibrationReferencePointDepth (Float64 &value, const unsigned long pos=0) const
 get CalibrationReferencePointDepth (300c,0124) More...
 
OFCondition getDelineatedRadiationFieldSize (Float64 &value, const unsigned long pos=0) const
 get DelineatedRadiationFieldSize (300c,0122) More...
 
OFCondition getSourceToSurfaceDistance (OFString &value, const signed long pos=0) const
 get SourceToSurfaceDistance (300a,0130) More...
 
OFCondition getSourceToSurfaceDistance (Float64 &value, const unsigned long pos=0) const
 get SourceToSurfaceDistance (300a,0130) More...
 
OFCondition setAbsorbedDoseToMetersetRatio (const Float64 value, const unsigned long pos=0)
 set AbsorbedDoseToMetersetRatio (300c,0121) More...
 
OFCondition setCalibrationDateTime (const OFString &value, const OFBool check=OFTrue)
 set CalibrationDateTime (0018,1203) More...
 
OFCondition setCalibrationReferencePointDepth (const Float64 value, const unsigned long pos=0)
 set CalibrationReferencePointDepth (300c,0124) More...
 
OFCondition setDelineatedRadiationFieldSize (const Float64 value, const unsigned long pos=0)
 set DelineatedRadiationFieldSize (300c,0122) More...
 
OFCondition setSourceToSurfaceDistance (const OFString &value, const OFBool check=OFTrue)
 set SourceToSurfaceDistance (300a,0130) More...
 

Private Attributes

OFBool EmptyDefaultItem
 internal flag used to mark the empty default item
 
DcmFloatingPointDouble AbsorbedDoseToMetersetRatio
 AbsorbedDoseToMetersetRatio (300c,0121) vr=FD, vm=1, type=1.
 
DcmDateTime CalibrationDateTime
 CalibrationDateTime (0018,1203) vr=DT, vm=1, type=2.
 
DcmFloatingPointDouble CalibrationReferencePointDepth
 CalibrationReferencePointDepth (300c,0124) vr=FD, vm=1, type=1.
 
DcmFloatingPointDouble DelineatedRadiationFieldSize
 DelineatedRadiationFieldSize (300c,0122) vr=FD, vm=2, type=1.
 
DcmDecimalString SourceToSurfaceDistance
 SourceToSurfaceDistance (300a,0130) vr=DS, vm=1, type=1.
 

Additional Inherited Members

- Protected Member Functions inherited from DRTTypes
virtual ~DRTTypes ()
 destructor. More...
 
- Static Protected Member Functions inherited from DRTTypes
static OFCondition addElementToDataset (OFCondition &result, DcmItem &dataset, DcmElement *element, const OFString &vm, const OFString &type, const char *moduleName=NULL)
 add given element to the dataset. More...
 
static OFCondition getElementFromDataset (DcmItem &dataset, DcmElement &element)
 get element from dataset More...
 
static OFCondition getStringValueFromElement (const DcmElement &element, OFString &stringValue, const signed long pos=0)
 get string value from element More...
 
static OFCondition getStringValueFromDataset (DcmItem &dataset, const DcmTagKey &tagKey, OFString &stringValue)
 get string value from dataset More...
 
static OFCondition putStringValueToDataset (DcmItem &dataset, const DcmTag &tag, const OFString &stringValue, const OFBool allowEmpty=OFTrue)
 put string value to dataset More...
 
static OFBool checkElementValue (DcmElement &element, const OFString &vm, const OFString &type, const OFCondition &searchCond=EC_Normal, const char *moduleName=NULL)
 check element value for correct value multiplicity and type More...
 
static OFCondition getAndCheckElementFromDataset (DcmItem &dataset, DcmElement &element, const OFString &vm, const OFString &type, const char *moduleName=NULL)
 get element from dataset and check it for correct value multiplicity and type. More...
 
static OFCondition getAndCheckStringValueFromDataset (DcmItem &dataset, const DcmTagKey &tagKey, OFString &stringValue, const OFString &vm, const OFString &type, const char *moduleName=NULL)
 get string value from dataset and check it for correct value multiplicity and type. More...
 

Detailed Description

Item class.

Constructor & Destructor Documentation

◆ Item() [1/2]

DRTDoseCalibrationConditionsSequence::Item::Item ( const OFBool  emptyDefaultItem = OFFalse)

(default) constructor

Parameters
emptyDefaultItemflag used to mark the empty default item

◆ Item() [2/2]

DRTDoseCalibrationConditionsSequence::Item::Item ( const Item copy)

copy constructor

Parameters
copyitem object to be copied

Member Function Documentation

◆ getAbsorbedDoseToMetersetRatio()

OFCondition DRTDoseCalibrationConditionsSequence::Item::getAbsorbedDoseToMetersetRatio ( Float64 &  value,
const unsigned long  pos = 0 
) const

get AbsorbedDoseToMetersetRatio (300c,0121)

Parameters
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1)
Returns
status, EC_Normal if successful, an error code otherwise

◆ getCalibrationDateTime()

OFCondition DRTDoseCalibrationConditionsSequence::Item::getCalibrationDateTime ( OFString value,
const signed long  pos = 0 
) const

get CalibrationDateTime (0018,1203)

Parameters
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1), -1 for all components
Returns
status, EC_Normal if successful, an error code otherwise

◆ getCalibrationReferencePointDepth()

OFCondition DRTDoseCalibrationConditionsSequence::Item::getCalibrationReferencePointDepth ( Float64 &  value,
const unsigned long  pos = 0 
) const

get CalibrationReferencePointDepth (300c,0124)

Parameters
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1)
Returns
status, EC_Normal if successful, an error code otherwise

◆ getDelineatedRadiationFieldSize()

OFCondition DRTDoseCalibrationConditionsSequence::Item::getDelineatedRadiationFieldSize ( Float64 &  value,
const unsigned long  pos = 0 
) const

get DelineatedRadiationFieldSize (300c,0122)

Parameters
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1)
Returns
status, EC_Normal if successful, an error code otherwise

◆ getSourceToSurfaceDistance() [1/2]

OFCondition DRTDoseCalibrationConditionsSequence::Item::getSourceToSurfaceDistance ( Float64 &  value,
const unsigned long  pos = 0 
) const

get SourceToSurfaceDistance (300a,0130)

Parameters
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1)
Returns
status, EC_Normal if successful, an error code otherwise

◆ getSourceToSurfaceDistance() [2/2]

OFCondition DRTDoseCalibrationConditionsSequence::Item::getSourceToSurfaceDistance ( OFString value,
const signed long  pos = 0 
) const

get SourceToSurfaceDistance (300a,0130)

Parameters
valuereference to variable in which the value should be stored
posindex of the value to get (0..vm-1), -1 for all components
Returns
status, EC_Normal if successful, an error code otherwise

◆ isEmpty()

OFBool DRTDoseCalibrationConditionsSequence::Item::isEmpty ( )

check if item is empty

Returns
OFTrue if item is empty, OFFalse otherwise

◆ isValid()

OFBool DRTDoseCalibrationConditionsSequence::Item::isValid ( ) const

check if item is valid, i.e. not the empty default item

Returns
OFTrue if item is valid, OFFalse otherwise

◆ operator=()

Item & DRTDoseCalibrationConditionsSequence::Item::operator= ( const Item copy)

assignment operator

Parameters
copyitem object to be copied
Returns
reference to this object

◆ read()

OFCondition DRTDoseCalibrationConditionsSequence::Item::read ( DcmItem item)

read elements from sequence item

Parameters
itemreference to DICOM sequence item from which the elements should be read
Returns
status, EC_Normal if successful, an error code otherwise

◆ setAbsorbedDoseToMetersetRatio()

OFCondition DRTDoseCalibrationConditionsSequence::Item::setAbsorbedDoseToMetersetRatio ( const Float64  value,
const unsigned long  pos = 0 
)

set AbsorbedDoseToMetersetRatio (300c,0121)

Parameters
valuevalue to be set (should be valid for this VR)
posindex of the value to be set (0..vm-1), vm=1
Returns
status, EC_Normal if successful, an error code otherwise

◆ setCalibrationDateTime()

OFCondition DRTDoseCalibrationConditionsSequence::Item::setCalibrationDateTime ( const OFString value,
const OFBool  check = OFTrue 
)

set CalibrationDateTime (0018,1203)

Parameters
valuevalue to be set (single value only) or "" for no value
checkcheck 'value' for conformance with VR (DT) and VM (1) if enabled
Returns
status, EC_Normal if successful, an error code otherwise

◆ setCalibrationReferencePointDepth()

OFCondition DRTDoseCalibrationConditionsSequence::Item::setCalibrationReferencePointDepth ( const Float64  value,
const unsigned long  pos = 0 
)

set CalibrationReferencePointDepth (300c,0124)

Parameters
valuevalue to be set (should be valid for this VR)
posindex of the value to be set (0..vm-1), vm=1
Returns
status, EC_Normal if successful, an error code otherwise

◆ setDelineatedRadiationFieldSize()

OFCondition DRTDoseCalibrationConditionsSequence::Item::setDelineatedRadiationFieldSize ( const Float64  value,
const unsigned long  pos = 0 
)

set DelineatedRadiationFieldSize (300c,0122)

Parameters
valuevalue to be set (should be valid for this VR)
posindex of the value to be set (0..vm-1), vm=2
Returns
status, EC_Normal if successful, an error code otherwise

◆ setSourceToSurfaceDistance()

OFCondition DRTDoseCalibrationConditionsSequence::Item::setSourceToSurfaceDistance ( const OFString value,
const OFBool  check = OFTrue 
)

set SourceToSurfaceDistance (300a,0130)

Parameters
valuevalue to be set (single value only) or "" for no value
checkcheck 'value' for conformance with VR (DS) and VM (1) if enabled
Returns
status, EC_Normal if successful, an error code otherwise

◆ write()

OFCondition DRTDoseCalibrationConditionsSequence::Item::write ( DcmItem item)

write elements to sequence item

Parameters
itemreference to DICOM sequence item to which the elements should be written
Returns
status, EC_Normal if successful, an error code otherwise

The documentation for this class was generated from the following file:


Generated on Tue Dec 19 2023 for DCMTK Version 3.6.8 by Doxygen 1.9.4