Activity
From 2021-01-25 to 2021-02-23
2021-02-19
-
16:25 Bug #787 (WontFix): DCMTK 3.6.2 compilation fails when creating static binaries due to libxml2 dependency
- This issue has meanwhile been fixed in the build scripts for CMake based builds. We will not fix it for the (deprecat...
-
16:21 Feature #966 (Closed): Describe "-" as special name for stdin/stdout in manpages
- Starting with release 3.6.6 (commit #f1689130d), DCMTK can read DICOM files from stdin and write DICOM files to stdou...
2021-02-09
-
12:24 Conformance #962 (Closed): Add minimal support for Supplement 212: XA Protocol Storage
- Added required changes with commit ddab86232.
2021-01-27
-
16:00 Conformance #960 (Closed): Add support for CP-2053: Mammography CAD SR Value Types
- Closed with commit #c67aefc9b.
2021-01-26
-
21:46 Conformance #962 (Closed): Add minimal support for Supplement 212: XA Protocol Storage
- See: ftp://medical.nema.org/medical/Dicom/final/sup212_ft_XA_Protocol_Storage.pdf
-
21:41 Conformance #961 (Closed): Add support for CP-2023: Clarify missing numeric measurement value in SR
- > Rationale for Correction:
> Unlike all other SR Content Items, the value of the NUM (the Measured Value Sequence)... -
21:26 Conformance #960 (Closed): Add support for CP-2053: Mammography CAD SR Value Types
- > Rationale for Correction:
>
> When the Value Type UIDREF was added to Mammography CAD SR templates, dating back ...
Also available in: Atom